Abstract

Real time spectroscopic ellipsometry (RTSE) was used to monitor and control the depth of etching into a bulk GaAs wafer. Lateral interference due to patterning is the mechanism by which this optical technique, normally used for thin film measurement, can determine etch depth into bulk material. Scalar analysis permits fast data fitting and real time control. GaAs wafers were patterned with photoresist in line or square patterns with periods of 10, 20, or 40 μm, and etched in a solution of citric acid–hydrogen peroxide–de-ionized water. RTSE data were collected and simultaneously analyzed for etch depth. When the depth reached a preselected target value of up to 1.6 μm the etch was stopped. Final etch depth as measured by scanning electron microscopy was always within 5% of the target depth. Ex situ spectroscopic ellipsometry analysis of the etched GaAs, with the photoresist removed, also agreed well with the RTSE results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.