Abstract

The High Temperature Gas Reactor (HTGR) is considered as one of the reactor type for the future nuclear power plant. The Fuel Handling System (FHS) is one of the important system in HTGR as well as in development design of RDE (Reaktor Daya Eksperimen). In the FHS, the fuel pebble is transported pneumatically by compressor into the reactor core. Due to the carrier gas from a primary cooling system is a hot helium gas, so it should be cooled in obtaining better performance of compressor. The purpose of this work is to estimate the operating parameter of carrier gas cooler based on the variation for the cooling water flow rate and outlet temperature of cooler. In this analyses, the ChemCAD.6.4.1 program was used. Both inlet and outlet temperature of carrier gas have been set up as specified conditions. The result shows that the coolant mass flow rate could be operated at minimum of 0.4 kg/s. Meanwhile in the lower range up to 0.3 kg/s, it appears a pinch zone in the internal length of cooler. However, to avoid the saturation temperature of coolant (118.64°C and 1.90bar) the minimum mass flow rate of 1.0 kg/s was suggested. This estimation is useful to determine the best operating parameter in the design of FHS especially for the cooling flow rate requirements.The High Temperature Gas Reactor (HTGR) is considered as one of the reactor type for the future nuclear power plant. The Fuel Handling System (FHS) is one of the important system in HTGR as well as in development design of RDE (Reaktor Daya Eksperimen). In the FHS, the fuel pebble is transported pneumatically by compressor into the reactor core. Due to the carrier gas from a primary cooling system is a hot helium gas, so it should be cooled in obtaining better performance of compressor. The purpose of this work is to estimate the operating parameter of carrier gas cooler based on the variation for the cooling water flow rate and outlet temperature of cooler. In this analyses, the ChemCAD.6.4.1 program was used. Both inlet and outlet temperature of carrier gas have been set up as specified conditions. The result shows that the coolant mass flow rate could be operated at minimum of 0.4 kg/s. Meanwhile in the lower range up to 0.3 kg/s, it appears a pinch zone in the internal length of cooler. However, to av...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.