Abstract

In a prestressed concrete beam with external tendons, the tendon stress depends on the member deformation, and it cannot be determined from section analysis alone as in the bonded case. Previous work has been mainly on the ultimate stress in unbonded steel tendons, with little on unbonded fibre-reinforced polymer (FRP) tendons. To account for the relative slip between the unbonded tendon and concrete, the ratio of the equivalent plastic hinge length to the neutral axis depth is analysed using available test results. It is found that this ratio for unbonded partially prestressed concrete (UPPC) beams with external FRP tendons can also be treated as a constant as for those with unbonded steel tendons. A simple method for evaluation of the ultimate stress in either steel or FRP external tendons is therefore proposed. After suitable modifications, the equations currently adopted by various design codes can still be used to predict the ultimate stress in external FRP tendons of UPPC beams.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.