Abstract

The most relevant parameter for assessing the acoustical properties of insulation layers for floating floor applications is the dynamic stiffness. Besides the surface mass of the floor plate the dynamic stiffness influences the reduction in impact sound pressure level of a floating floor. According to the formerly German measurement standard DIN 52214 the dynamic stiffness of impact sound insulation materials had to be measured after applying a short-term pre-load of 50 kNm−2. This pre-load does not reflect the conditions in the field and has been withdrawn in EN 29052-I. By comparison of measured field data for floor constructions with estimated data based on measurements with and without pre-load it is shown, that the new measurement procedure in connection with a more detailed estimation of the building element properties leads to a more accurate prediction of impact sound insulation in dwellings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.