Abstract

A method is presented that employs soil moisture measurements and lysimetric reference evapotranspiration data to estimate a soil hydraulic factor for estimating soil evaporation. Soil evaporation is a complicated process. The soil evaporation process has two main stages. In this study, soil hydraulic factor was used to estimate soil evaporation under dune sand mulch. The soil hydraulic factor was derived from small pan evaporation data and soil evaporation data from dune sand soil columns. Dune sand soil columns were saturated and gravitational water was drained. The dune sand soil columns were then covered by dry Tottori dune sand soil of 0 cm, 2 cm and 5 cm thickness. Soil evaporation from these columns was measured gravimetrically. Potential evaporation was determined from small evaporation pans placed alongside the dune sand soil columns. Water was applied to three weighing lysimeters (for measuring actual soil evaporation) in a glasshouse to the field capacity of the dune sand soil. The weighing lysimeters were also covered by the dune sand soil of 0 cm, 2 cm and 5 cm thickness and that was dried naturally. Cumulative soil evaporation from dune sand soil columns and cumulative potential evaporation from small evaporation pans was used to determine the soil hydraulic factor under the three dune sand mulch treatments. The soil hydraulic factor was then used to estimate soil evaporation under natural drying conditions in the glasshouse. Estimated cumulative soil evaporation was compared with measured cumulative soil evaporation. The soil hydraulic factor overestimated cumulative soil evaporation during the falling rate stage of soil evaporation under 0 cm and 2 cm sand mulch. Adjusting the estimation by subtracting the difference between the estimated and the measured cumulative soil evaporation at the point where the square root of cumulative potential evaporation was equal to the soil hydraulic factor from the estimates moved the values closer to the actual measured. The soil hydraulic factor overestimated cumulative soil evaporation during the whole drying period under 5 cm dune sand soil mulch. The adjustment of the estimates did not move the values as close to the actual measured as in the 2 cm mulch. Using the soil hydraulic factor gave better estimates of cumulative soil evaporation during the constant rate stage under 0 cm and 2 cm sand mulch than under 5 cm sand mulch.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.