Abstract

The potential of near-infrared reflectance spectroscopy (NIRS) for the simultaneous analysis of seed weight, total oil content and its fatty acid composition in intact single seeds of rapeseed was studied. A calibration set of 530 single seeds was analysed by both NIRS and gas-liquid chromatography (GLC) and calibration equations for the major fatty acids were developed. External validation with a set of 75 seeds demonstrated a close relationship between NIRS and GLC data for oleic (r = 0.92) and erucic acid (r = 0.94), but not for linoleic (r = 0.75) and linolenic acid (r = 0.73). Calibration equations for seed weight and oil content were developed from a calibration set of 125 seeds. A gravimetric determination was used as reference method for oil content. External validation revealed a coefficient of correlation between NIRS and reference methods of 0.92 for both traits. The performance of the calibration equations for oleic and erucic acid was further studied by analysing two segregating F2 seed populations not represented in the calibration set. The results demonstrated that a reliable selection for both fatty acids in segregating populations can be made by using NIRS. We concluded that a reliable estimation of seed weight, oil content, oleic acid and erucic acid content in intact, single seeds of rapeseed is possible by using NIRS technique.