Abstract
A model-free deconvolution method is proposed for evaluating the frequency distribution function of organ transit times. The deconvolution is treated as a nonlinear constrained optimization problem and it is solved by using a modified constrained variable metric approach. The only constraint implemented in the solution is that all the discrete transport function values are not allowed to become negative. The method is tested on model mathematical systems of known analytical transport functions. The tests are performed on systems that included noise in both the input and output functions. The criteria of successful deconvolution are the reconvolution error and, most importantly, the deviation of the computed transport function from the known analytical one. The proposed method is then applied, as a pilot experiment, to biological data obtained from an isolated, perfused rabbit lung preparation contained within a plethysmograph. The results indicate that this type of deconvolution produces stable estimates which faithfully follow the analytical function while negating the need to assume either any functional form for the behavior of the transport function or any educated initial guess of its values.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.