Abstract

Optimal insertion angle of mammalian stereocilia is estimated from the finite element analysis of the tip motion of outer hair cells (OHCs) stereocilia. The OHC stereocilia motion in the acousticolateral system appears to result in the mechanoelectrical transduction channels. Deflection of the hair bundle towards the tallest row of stereocilia causes increased probability of opening of ion channels. In this work, we focus on one of the physical features of the OHC stereocilium, the initial insertion angle of the tallest row into the tectorial membrane (TM), and its effects on the stereocilia's deflection motion. A three-dimensional model was built for the tallest stereocilium and the TM at the region where the best frequency was 500Hz. The mechanical interactions between the embedded stereocilia and the TM have been implemented into the finite element simulation. We found that, the optimum insertion angle of the tallest stereocilium into the TM was 69.8°, where the stereocilium is maximally deflected. This quantity is consistent with the histological observation obtained from the literature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.