Abstract

The 15-year storage aged GFRP composite dumbbell-shaped specimens were immersed in concentrated HCl at different temperatures and times. The Young modulus, which is a yardstick of stiffness of the samples, was measured. The long-term stiffness at any time and temperature was predicted by using the master curve of stiffness obtained based on our accelerated testing results. In the first, second, third, and fourth years of the prediction the stiffness was 6800, 6400, 5550, and 5150 MPa, respectively. SEM micrographs of typical samples showed failure mode at the interface. The strength showed reduction due to degradation of fiber/matrix interfacial bond. The best match of our prediction obtained by using error function was between the first and the third years.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.