Abstract

The principle of floating wire technique is introduced. Wire trace and current are measured through a dipole magnet through 180° in the horizontal plane. Measurements are made for testing the reflection magnet performance of neutral beam injector of experimental advanced superconducting tokamak. The magnetic field intensity is estimated by wire current, wire tension and radius of wire orbit. The excitation coefficient of the reflection magnet is about 1.07, which is in agreement with requirement of engineering design. Using the excitation coefficient, the operation guide data of reflection magnet is given with ion energy, \( I = 40.99\sqrt E \).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.