Abstract

Error fields in tokamaks are small departures from the exact axisymmetry of the ideal magnetic field configuration. Their reduction below a threshold value by the error field correction coils is essential since sufficiently large static error fields lead to discharge disruption.The error fields are originated not only by magnets fabrication and installation tolerances, by the joints and by the busbars, but also by the presence of ferromagnetic elements. It was shown that superconducting joints, feeders and busbars play a secondary effect; however in order to estimate of the importance of each possible error field source, rough evaluations can be very useful because it can provide an order of magnitude of the correspondent effect and, therefore, a ranking in the request for in depth analysis. The paper proposes a two steps procedure. The first step aims to get the approximate magnetization state of ferromagnetic parts; the second aims to estimate the full 3D error field over the whole volume using equivalent sources for magnetic masses and taking advantage from well assessed approximate closed form expressions, well suited for the far distance effects.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call