It is common practice to represent a composite electrical winding as an equivalent lumped anisotropic material as this greatly simplifies a thermal model and reduces computation times. Existing techniques for estimating the bulk thermal properties of such composite materials use either analytical, numerical, or experimental approaches; however, these methods exhibit a number of drawbacks and limitations regarding their applicability. In this paper, a numerical thermal conductivity and analytical specific heat capacity estimation technique is proposed. The method is validated experimentally against three winding samples with differing configuration. A procedure is presented which enables bulk thermal properties to be estimated with a minimal need for experimental measurement, thereby accelerating the thermal modeling process. The proposed procedure is illustrated by the modeling of three coil exemplars with differing windings. Experimental thermal transients obtained by dc test of the coils show close agreement with a lumped-parameter thermal model utilizing estimated material data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.