Abstract

This paper describes electrical equivalent circuit models of cell–capillary admittance during injection of a living cell and presents a measurement system to estimate corresponding frequency responses during microinjection tests. Since the admittance estimate is calculated from data collected during injection, the amount of data is limited. To overcome this constraint, the approach proposed in this paper takes advantage of properties of periodic pseudo random binary sequence (PRBS) excitation signal and avoids end effect anomalies of correlation calculation. The fast and accurate estimation is used to detect the degree of contact during cell injection and to detect breakage and clogging of capillary during a sequence of multiple operations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.