Abstract

We present a spectral image processing method for estimating the distribution of the reduced electric field E/N for Hermstein’s glow corona discharge. This method analyzes spectral images of the discharge taken by an intensified charge-coupled device camera with ultra-narrow band pass filters at the pixel level. The method requires a shorter measurement time than optical emission spectroscopy and can reveal finer details of the spatial distribution. Experiments showed that the E/N of discharge at the tip of the electrode locally increases with an increase in the applied voltage. In particular, E/N at the tip of the electrode reaches a high value just before breakdown. Based on the maximum acquired values, the breakdown of discharge is estimated to occur when E/N ≥ 270 × 10−21–340 × 10−21 V m2. This study is expected to contribute to monitoring the discharge state of electrical equipment to prevent breakdown and ensure safety.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.