Current distribution in the electric traction system is an important factor regarding the electromagnetic influences on the surrounding metallic structures. The current value directly determines the magnetic field and consequently coupling of the systems. A single rail traction system can be equipped with return conductor. The return current flowing through return conductor has an opposite direction of supply current and decreases coupling and interferences.This paper presents the AC current distribution for both designs, with and without return conductor. Also, the soil resistivity is varied. The higher the soil resistivity, the higher is the amount of return current in rails and return conductor. The different construction of return conductor results in different impedance of return path. The relations of return conductor construction and return current value are analysed.Lightning can directly impact different traction system elements such as contact network, tower or return wire. The current distributions in several cases of lightning impacting different traction system elements are presented.