Abstract
This study validated duplex ultrasound measurement of brachial artery volume flow (VF) as predictor of dialysis access flow maturation and successful hemodialysis. Duplex ultrasound was used to image upper extremity dialysis access anatomy and estimate access VF within 1 to 2 weeks of the procedure. Correlation of brachial artery VF with dialysis access conduit VF was performed using a standardized duplex testing protocol in 75 patients. The hemodynamic data were used to develop brachial artery flow velocity criteria (peak systolic velocity and end-diastolic velocity) predictive of three VF categories: low (<600 mL/min), acceptable (600-800 mL/min), or high (>800 mL/min). Brachial artery VF was then measured in 148 patients after a primary (n = 86) or revised (n = 62) upper extremity dialysis access procedure, and the VF category correlated with access maturation or need for revision before hemodialysis usage. Access maturation was conferred when brachial artery VF was >600 mL/min and conduit imaging indicated successful cannulation based on anatomic criteria of conduit diameter >5 mm and skin depth <6 mm. Measurements of VF from the brachial artery and access conduit demonstrated a high degree of correlation (R(2) = 0.805) for autogenous vein (n = 45; R(2) = 0.87) and bridge graft (n = 30; R(2) = 0.78) dialysis accesses. Access VF of >800 mL/min was predicted when the brachial artery lumen diameter was >4.5 mm, peak systolic velocity was >150 cm/s, and the diastolic-to-systolic velocity ratio was >0.4. Brachial artery velocity spectra indicating VF <800 mL/min was associated (P < .0001) with failure of access maturation. Revision was required in 15 of 21 (71%) accesses with a VF of <600 mL/min, 4 of 40 accesses (10%) with aVF of 600 to 800 mL/min, and 2 of 87 accesses (2.3%) with an initial VF of >800 mL/min. Duplex testing to estimate brachial artery VF and assess the conduit for ease of cannulation can be performed in 5 minutes during the initial postoperative vascular clinic evaluation. Estimation of brachial artery VF using the duplex ultrasound, termed the "Fast, 5-min Dialysis Duplex Scan," facilitates patient evaluation after new or revised upper extremity dialysis access procedures. Brachial artery VF correlates with access VF measurements and has the advantage of being easier to perform and applicable for forearm and also arm dialysis access. When brachial artery velocity spectra criteria confirm a VF >800 mL/min, flow maturation and successful hemodialysis are predicted if anatomic criteria for conduit cannulation are also present.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.