Abstract

The filtration of fecal coliform from a secondary clarifier effluent was investigated using direct rapid sand filters as tertiary wastewater treatment on a pilot scale. The effect of the flocculation dose, flow loading rate, and grain size on fecal coliform removal was determined. Direct rapid sand filters can remove 0.6-1.5 log-units of fecal coliform, depending on the loading rate and grain size distribution. Meanwhile, the flocculation dose has little effect on coliform removal, and increasing the loading rate and/or grain size decreases the bacteria removal efficiency. A model was then developed for the removal process. Bacteria elimination and inactivation both in the water phase and the sand bed can be described by first-order kinetics. Removal was successfully simulated at different loading rates and grain size distributions and compared with the data obtained using pilot-scale filters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.