Abstract

The design of a power converter must guarantee that the operating junction temperatures thetavj of all devices do not exceed their limits under all specified operating conditions. Usually, this is ensured by a simulative or analytical junction temperature estimation based on simple electrical and thermal models and semiconductor datasheet values. This paper discusses the difficulties and quantifies the limitations of this approach on the example of a three-level neutral point clamped voltage source converter (NPC VSC) with insulated gate bipolar transistors. The calculations are compared to the results of direct junction temperature measurements with an infrared camera. The paper also provides the experimental proof for the unequal loss and junction temperature distribution in the three-level NPC VSC

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.