Abstract

This paper presents the results of a study on the dimensional accuracy analysis of models produced by 3D printing technology—Fused Filament Fabrication (FFF). Geometric measurements were conducted using a dial caliper, a 3D scanner and a coordinate measuring machine. In addition, a statistical analysis of the test results was carried out, considering the division into different numbers of test samples (3, 5, 10, 20, 30). The analysis of the test results made it possible to assess the influence of the measuring tools used and the number of samples tested on the final measurement result, as well as to determine the consequences associated with it.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.