Abstract

Direct measurements of sewer leakage with continuous dosing of tracers are often considered too imprecise for practical applications. However, no mathematical framework for data analysis is reported in literature. In this paper, we present an improved experimental design and data analysis procedure together with a comprehensive framework for uncertainty assessment. Test runs in a 700 m-long watertight sewer showed no significant bias and a very high precision of the methodology. The standard error in the results was assessed to 2.6% of the labeled flow with a simplified model. It could be reduced to 1.2% when a dynamic data analysis procedure was applied. The major error contribution was caused by transient transport phenomena, which suggests that careful choosing of the experimental time is more important than the choice of a very specific tracer substance. Although the method is not intended to replace traditional CCTV inspections, it can provide complementary information for rational rehabilitation planning.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.