Abstract

BackgroundTumor motion may compromise the accuracy of liver stereotactic radiotherapy. In order to carry out a precise planning, estimating liver tumor motion during radiotherapy has received a lot of attention. Previous approach may have difficult to deal with image data corrupted by noise. The iterative closest point (ICP) algorithm is widely used for estimating the rigid registration of three-dimensional point sets when these data were dense or corrupted. In the light of this, our study estimated the three-dimensional (3D) rigid motion of liver tumors during stereotactic liver radiotherapy using reconstructed 3D coordinates of fiducials based on the ICP algorithm.MethodsFour hundred ninety-five pairs of orthogonal kilovoltage (KV) images from the CyberKnife stereo imaging system for 12 patients were used in this study. For each pair of images, the 3D coordinates of fiducial markers inside the liver were calculated via geometric derivations. The 3D coordinates were used to calculate the real-time translational and rotational motion of liver tumors around three axes via an ICP algorithm. The residual error was also investigated both with and without rotational correction.ResultsThe translational shifts of liver tumors in left-right (LR), anterior-posterior (AP),and superior-inferior (SI) directions were 2.92 ± 1.98 mm, 5.54 ± 3.12 mm, and 16.22 ± 5.86 mm, respectively; the rotational angles in left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions were 3.95° ± 3.08°, 4.93° ± 2.90°, and 4.09° ± 1.99°, respectively. Rotational correction decreased 3D fiducial displacement from 1.19 ± 0.35 mm to 0.65 ± 0.24 mm (P<0.001).ConclusionsThe maximum translational movement occurred in the SI direction. Rotational correction decreased fiducial displacements and increased tumor tracking accuracy.

Highlights

  • Traditional radiotherapy can prolong survival for patients with resectable liver cancers [1] but it offers limited efficacy for the treatment of unresectable primary and metastatic liver cancers mainly due to the low whole liver tolerance to radiotherapy [2, 3]

  • Target motion may compromise the accuracy of liver stereotactic radiotherapy

  • We aim to estimate the intrafractional rigid motion of liver tumor based on real-time KV X-ray images acquired by CyberKnife stereo imaging system via a quaternion-based iterative closest point (ICP) algorithm

Read more

Summary

Introduction

Traditional radiotherapy can prolong survival for patients with resectable liver cancers [1] but it offers limited efficacy for the treatment of unresectable primary and metastatic liver cancers mainly due to the low whole liver tolerance to radiotherapy [2, 3]. Target motion may compromise the accuracy of liver stereotactic radiotherapy. According to Velec et al [14], 70% patients involved in their study treated with liver stereotactic radiotherapy had accumulated dose deviations relative to the planned static prescription dose > 5%, ranging from − 15 to 5% in tumors and 42 to 8% in. Liver tumors are difficult to visualize on X-ray images due to their low contrast against soft tissues around. Tumor motion may compromise the accuracy of liver stereotactic radiotherapy. In order to carry out a precise planning, estimating liver tumor motion during radiotherapy has received a lot of attention. In the light of this, our study estimated the three-dimensional (3D) rigid motion of liver tumors during stereotactic liver radiotherapy using reconstructed 3D coordinates of fiducials based on the ICP algorithm

Objectives
Methods
Results
Conclusion