Abstract

Inertial and magnetic sensors are very suitable for ambulatory monitoring of human posture and movements. However, ferromagnetic materials near the sensor disturb the local magnetic field and, therefore, the orientation estimation. A Kalman-based fusion algorithm was used to obtain dynamic orientations and to minimize the effect of magnetic disturbances. This paper compares the orientation output of the sensor fusion using three-dimensional inertial and magnetic sensors against a laboratory bound opto-kinetic system (Vicon) in a simulated work environment. With the tested methods, the difference between the optical reference system and the output of the algorithm was 2.6 degrees root mean square (rms) when no metal was near the sensor module. Near a large metal object instant errors up to 50 degrees were measured when no compensation was applied. Using a magnetic disturbance model, the error reduced significantly to 3.6 degrees rms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.