Abstract

The purpose of the study is to obtain estimates of limits on uncontrolled beam losses of heavy ions for allowing hands-on maintenance at a heavy-ion linac for a rare isotope beam facility. Semiempirical formulas are used to estimate dose equivalent rates from activated accelerator components for 1 W/m uncontrolled losses of protons up to 1 GeV. The estimated dose rates after a 100-day irradiation time, 4-h postshutdown cooling time are compared to a hands-on maintenance limit of 1 mSv/h (100 mrem/h) at 30 cm. The transport codes PHITS and MCNP5 and activation code DCHAIN-SP 2001 are used to verify the estimate for proton losses and to obtain limits on heavy-ion beam losses that will satisfy the hands-on maintenance dose rate limit.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call