Abstract

Accurate and rapid diagnosis of chorioamnionitis poses a major diagnostic dilemma. We previously reported that leukocyte esterase activity in amniotic fluid, as measured by dipstick assay, could be used as an aid in the diagnosis of chorioamnionitis. This study examines the effectiveness of an in vitro spectrophotometric assay of esterase activity in amniotic fluid. We define baseline levels of esterase activity in uninfected amniotic fluid and demonstrate a quantitative increase when infection is present. Fifty-seven amniotic fluid samples obtained at second- and third-trimester amniocenteses were divided into three parts, one for culture and two for a comparison of esterase activities by the dipstick and spectrophotometric methods. In this study, the spectrophotometric assay, because of its higher specificity and sensitivity in the determination of elevated esterase activity, was shown to be more reliable for predicting chorioamnionitis than either the dipstick or culture method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call