Abstract

ObjectivesTo analyse the state of refractive surgery with Visian ICL phakic lens implantation in Spain, indicating the mean ranges of implanted powers, visual and refractive outcomes obtained and safety and efficacy indices. MethodThis is a population-based, cross-sectional, descriptive, analytical, retrospective, multicentre study in which each co-author collected data from at least the last 10 patients (up to a maximum of 30) with Visian ICL phakic lens implantation. One eye from each subject was randomly selected for study inclusion, and the variables analysed were: age, gender, visual acuities with and without correction pre and post-surgery, preoperative and residual refraction, keratometry, endothelial cellular density, anterior chamber depth from endothelium, central corneal pachymetry, intraocular pressure, white-white, implanted lens (power and size), expected and achieved spherical equivalent (SEQ) post-surgery at one month after surgery. ResultsA sample of 140 eyes was obtained from 140 patients with a mean age of 31.35±7.28 years. Mean preoperative SEQ was −6.33±3.69D, mean visual acuities with correction was 0.96±0.16, anterior chamber depth was 3.30±0.29mm, white-white 12.02±0.40mm, central corneal pachymetry 535.03±37.68μm, endothelial cellular density 2684.37±313.74cels/mm2 and intraocular pressure 14.84±2.59mmHg. A percentage of 66.4 of the implanted lenses were spherical ICLs and 33.6% toric, with a mean power of −7.81±4.09D and a mean cylinder of 2.27±1.23D. A percentage of 5.7 of the implanted lenses were hypermetropic. The mean SEQ target selected was +0.04±0.27D. A percentage of 45.69 of the implanted lenses were of size 13.2mm, with the remaining 37.93, 12.93 and 3.45% being of sizes 12.6, 12.1 and 13.7mm, respectively. At one month after surgery a residual SEQ of −0.01±0.31D was obtained. The efficacy and safety indices were 1.06±0.18 and 1.10±0.19, respectively. The mean central vault was 508.80±201.04μm. The accuracy between the calculated SEQ and the obtained SEQ was 99.3% for spherical lenses and 88.2% for cylinder correction. The mean ECD at one month after surgery was 2805.53±273.30cels/mm2. The mean intraocular pressure was 13.98±2.57mmHg. ConclusionsIn this group of analysis has been shown that ICL implantation is a safe procedure in the short term with a high refractive predictability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call