Abstract
Abstract In this research, the analysis methodology for Maanshan PWR nuclear power plant (NPP) ATWS (Anticipated Transient Without Scram) is established by using RADTRAD code. This methodology can evaluate the dose at Exclusion Area Boundary (EAB), Low Population Zone (LPZ), and control room for the Maanshan ATWS. In addition, there are four leakage pathways in the Maanshan ATWS that are containment leakage, containment low volume purge, steam generator leakage, and ESF leakage. Therefore, for these leakage pathways, the RADTRAD models are established. Finally, according to the analysis results, they are below the criteria of 10 CFR 100.11 for the EAB and LPZ and Standard Review Plan (SRP) for the control room. Additionally, the steam generator leakage gives the maximum dose in these leakage pathways.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.