Abstract

Recently, veno-venous extracorporeal membrane oxygenation (V-V ECMO) has been commonly used in the world to support patients with severe respiratory failure. However, V-V ECMO is a new technology compared to veno-arterial extracorporeal membrane oxygenation and cardiopulmonary bypass, and there are few reports of basic research. Although continuing research is desired, clinical research that standardizes conditions such as patients' background characteristics is difficult. The purpose of this study was to establish a simple and stably maintainable miniature V-V ECMO model to study the mechanisms of the biological reactions in circulation during V-V ECMO. The V-V ECMO system consisted of an original miniature membrane oxygenator, polyvinyl chloride tubing line, and roller pump. The priming volume of this system was only 8mL. Polyethylene tubing was used to cannulate the right femoral vein as the venous return cannula for the V-V ECMO system. A 16-G cannula was passed through the right internal jugular vein and advanced into the right atrium as the conduit for venous uptake. The animals were divided into 2 groups: SHAM group and V-V ECMO group. V-V ECMO was initiated and maintained at 50-60mL/kg/min, and oxygen was added into the oxygenator during V-V ECMO at a concentration of 100% (pump flow:oxygen=1:10). Blood pressure was measured continuously, and blood cells were measured by blood collection. During V-V ECMO, the blood pressure and hemodilution rate were maintained around 80 mmHg and 20%, respectively. Hb was kept at >10g/dL, and V-V ECMO could be maintained without blood transfusion. It was possible to confirm oxygenation of and carbon dioxide removal from the blood. Likewise, the pH was adequately maintained. There were no problems with this miniature V-V ECMO system, and extracorporeal circulation progressed safely. In this study, a novel miniature V-V ECMO model was established in the rat. A miniature V-V ECMO model appears to be very useful for studying the mechanisms of the biological reactions during V-V ECMO and to perform basic studies of circulation assist devices.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.