Abstract

BackgroundNeuropilins (Nrps) are a new type of broad‐spectrum tumor marker. Currently, a method for accurate simultaneous quantification of Nrps is not available. We aimed to develop a bead‐based and duplexed flow cytometric assay that could be used for accurate and simultaneous quantification of Nrp1 and Nrp2 for scientific research or clinical diagnosis.MethodsWe coupled anti‐human Nrp1‐11# mAb and anti‐human Nrp2‐C3 mAb to magnetic beads 18# and 25#, respectively. Capturing antibodies and detecting antibodies were then combined to detect Nrps by a bead‐based Luminex assay, which was subsequently applied to quantify Nrps in clinical serum samples.ResultsThe results showed that the detection value of Nrps ranged from 10 to 100 000 pg/mL for Nrp1 and from 25 to 100 000 pg/mL for Nrp2. The detection sensitivity reached 10 pg/mL for Nrp1 and 24.8 pg/mL for Nrp2. Intra‐assay variances ranged from 1.0% to 2.6% for Nrp1 and from 2.9% to 4.0% for Nrp2, and interassay variances ranged from 1.5% to 6.4% for Nrp1 and from 4.2% to 8.1% for Nrp2. The Nrp1 and Nrp2 recoveries were 96.6%‐103.6% and 95.6%‐102.3%, respectively. Irrelevant antigens had no interference in the paired‐detection system, and the mean fluorescence intensity (MFI) values were stable for months.ConclusionA bead‐based, duplexed flow cytometric assay (xMAP® technology) was developed to detect Nrp1 and Nrp2. The assay provided rapid, high‐throughput results and was much more sensitive, specific, reproducible, and stable than existing assays. In addition, this assay could be applied in early‐stage cancer screening, tumor malignancy analysis, and prognosis assessment.

Highlights

  • BackgroundA method for accurate simultaneous quantification of Nrps is not available

  • Tumor markers play an important role in clinical diagnosis and tumor treatment

  • Irrelevant antigens had no interference in the paired‐detection system, and the mean fluorescence intensity (MFI) values were stable for months

Read more

Summary

Background

A method for accurate simultaneous quantification of Nrps is not available. We aimed to develop a bead‐based and duplexed flow cytometric assay that could be used for accurate and simultaneous quantification of Nrp[1] and Nrp[2] for scientific research or clinical diagnosis. The detection sensitivity reached 10 pg/mL for Nrp[1] and 24.8 pg/mL for Nrp[2]. Conclusion: A bead‐based, duplexed flow cytometric assay (xMAP® technology) was developed to detect Nrp[1] and Nrp[2]. The assay provided rapid, high‐throughput results and was much more sensitive, specific, reproducible, and stable than existing assays. This assay could be applied in early‐stage cancer screening, tumor malignancy analysis, and prognosis assessment. KEYWORDS bead‐based immunoassay, duplex flow cytometry, Neuropilins, xMAP technology

| INTRODUCTION
| MATERIALS AND METHODS
| DISCUSSION
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.