Abstract

The global COVID-19 pandemic has resulted in a greater interest in improving the ventilation of indoor environments in order to remove aerosolized virus and thus reduce transmission. Air purification systems have been proposed as a solution to improve aerosol removal. The aim is to determine the efficacy of air purification systems in reducing the viral load in environmental air of a room. A containment room equipped with HEPA filter on air intake and exhaust was constructed. It was connected via an inlet with the BSL-2 facility. From the BSL-2, Feline Corona virus (FCoV) loaded aerosols were released into the containment room. After nebulization, air sampling was performed to determine the viral load in air prior to assessing the clean air delivery rate of the air purification systems. The infectivity of the captured viruses was also examined. The air purification systems realized a 97 to 99% reduction in viral load in air in one hour. Captured infectious FCoV was reduced by 99.9% to 99.99% by use of an ESP technology. The air purification systems, using ESP technology or HEPA filter, reduce the viral load in air. The ESP purifiers inactivate captured FCoV viruses. Therefore, air purification systems can be used as an adjunctive infection control measure.