Abstract

Recently developed microform measurement techniques have reduced the measurement uncertainties in the geometry of Rockwell diamond indenters. It is now possible to establish standard grade Rockwell diamond indenters characterized by high geometry uniformity, high hardness performance uniformity, interchangeability and reproducibility. By using the standard indenters under different national standard machines and a standardized testing cycle, a worldwide unified Rockwell hardness scale could be established with metrological traceability, stability and reproducibility. Geometrical measurements and hardness tests in five laboratories have shown that tightly controlled indenter geometry can significantly improve the consistency of Rockwell C hardness (HRC) measurements. These results support the feasibility of establishing a worldwide unified HRC scale with an expanded uncertainty ( k=2) of approximately ±0.2 HRC and without significant bias with respect to an ideal scale.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.