Abstract

In this study, we devised a diagnostic platform harnessing a combination of recombinase polymerase amplification (RPA) and the clustered regularly interspaced short palindromic repeats (CRISPR)/Cas12a system. Notably, this platform obviates the need for intricate equipment and finds utility in diverse settings. Two result display methods were incorporated in this investigation: the RPA-Cas12a-fluorescence method and the RPA-Cas12a-LFS (lateral flow strip). Upon validation, both display platforms exhibited no instances of cross-reactivity, with seven additional types of fungal pathogens responsible for respiratory infections. The established detection limit was ascertained to be as low as 102 copies/µL. In comparison to fluorescence quantitative PCR, the platform demonstrated a sensitivity of 96.7%, a specificity of 100%, and a consistency rate of 98.0%.This platform provides expeditious, precise, and on-site detection capabilities, thereby rendering it a pivotal diagnostic instrument amenable for deployment in primary healthcare facilities and point-of-care settings.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call