Abstract
Multiple variables have been shown to influence early marginal bone loss around dental implants. Among these factors, the location of the microgap related to the alveolar crest, occlusion, crest module and soft tissue thickness were reported to be important factors for deciding the final outcome of the implant treatment. The purpose of this study was to establish a damping model to simulate the mechanical function of dental implants in the oral cavity. The experimental implant model consisted of a screw-type implant (10[Formula: see text]mm). The implant was placed into epoxy resin which was used to simulate bone tissue. In this study, two kinds of epoxy resin were used: PL-1 (with elastic moduli of 2900[Formula: see text]MPa) and PL-2 (210[Formula: see text]MPa) were used to simulate cortical bone and cancellous bone, respectively. Above bone block, a soft lining material was used to simulate the soft tissue around implant. In addition, two-implant model with various distance between implants were established to discuss the effect of soft tissue effect on the damping factors (DF) of the implant system. A noninvasive impulse-forced vibration technique was used to detect the damping factors of the implant models as previous reported. Briefly, the signal excitation was detected through the micro-phone and sent to the spectrum analyzer. The frequency response was obtained from a vibration-time histogram using Fast Fourier Transform software. The DF value of the signal dental implant model was detected to be [Formula: see text]. This value is closed to the in vivo data that was reported previously. This result showed that the model established in this study is a validated model for damping analysis. Furthermore, the DF value of a dental implant surrounded with 3[Formula: see text]mm soft tissue ([Formula: see text]) is significantly higher than the implant with 2[Formula: see text]mm-surround soft tissue ([Formula: see text]). In addition, implant models with larger interval distance between implants showed higher DF values. According to the results of this study, it is reasonable to suggest that dental implant surrounded with higher amount soft tissue may reduce more vibration amplitude while an occlusal force was applied to a dental implant. This vibration reducing effect may be helpful to reduce alveolar bone resorption around implants.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.