Abstract

Background Children with esophageal foreign bodies are frequently seen by pediatric surgeons. Choking and dysphagia are common presentations; however, esophageal perforation has been reported. Historically, rigid esophagoscopy with extraction of the foreign body has been the recommended treatment. Alternatively, Foley balloon extraction is a safe and effective approach. Methods Over a 16-year period, 555 children presented with an esophageal foreign body. Retrospective analysis of the medical record was undertaken. Statistics were by univariate analysis. Results Two hundred ninety-eight boys and 257 girls presented with a mean age of 3.24 years. Dysphagia (37%) and drooling (31%) were the most common symptoms. Foreign bodies were lodged in the superior esophagus in 73%, and 88% of the objects were coins. Balloon extraction with fluoroscopy was performed in 468 children. Eighty percent of the objects were successfully removed with a mean fluoroscopy time of 2.2 min, and 8% were advanced into the stomach. The overall success rate was 88%, with failures necessitating rigid esophagoscopy under general anesthesia. Children younger than 1 year were the most likely to fail (25% failure rate). Airway aspiration never occurred. Significant savings in patient charges were observed with this approach. Conclusions Balloon extraction of pediatric esophageal foreign bodies is a safe and cost-effective procedure. This technique is applicable for infants, children, and adolescents. Experienced practitioners should be able to achieve greater than 80% success rate.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call