Abstract
1. The values of the diaphragm discharge coefficients which have moduli between 0.4 and 0.6 and are adopted in the national standards are higher than the corresponding experimentally obtained values. The mean-square error of the mean value of the basic diaphragm discharge coefficient in the range of 0.35 to 0.8 moduli varies between 0.05 and 0.12%, and the mean-square error of a series of measurements varies between 0.23 to 0.59% 2. The investigation of discharge coefficients of restricting devices in precision discharge-meters by means of modern method of experimental data analysis remains a pressing problem.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.