Abstract

A systematic computational study was performed in which hard films perfectly bonded to relatively soft substrates of the same modulus were indented using a sharp conical tip. Maximum indentation depths h max up to film thickness t were considered; resolved modulus was obtained from Oliver–Pharr analysis of unloading curves. Despite the elastic matching between film and substrate, it was found that for depths of penetration h on the same order of film thickness t, the resolved modulus exhibits a significant (>50%) decrease relative to input values. This is attributed to a ‘plastic hinge’ in the substrate that strongly affects pile-up around the indenter, as well as the volume of material that ‘springs back.’ Results shown for elastic-perfectly plastic systems suggest the importance of further parametric study. For discussion, results are compared with experimental results of rapidly quenched, small-volume Ni structures (‘splats’) on polished stainless steel substrates, where similar modulus decrease was observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.