Abstract

The objective of this paper is to describe the calibration test method and conditions for MEMS-based IMUs including accelerometers and gyroscopes. This method is mainly used to derive deterministic error bounds within the acceptable range of accuracy. After a detailed description of the error model, the calibration process, test procedure, and test results as well as practical challenges are discussed. The presented method is simple, cheap and fast that takes only a few hours for calibration and validation of these sensors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.