Abstract

Accurate femoral rotational alignment is of vital importance for successful total knee arthroplasty (TKA). The value of computer-assisted surgery TKA (CAS-TKA) in increasing the accuracy of femoral rotational alignment remains controversial. We hypothesize that outcomes are related to the severity of preoperative varus and valgus deformity and that CAS-TKA may be beneficial under certain circumstances. Between January 2007 and December 2013, patients with osteoarthritis and varus angulation in the mechanical axis (MA) ≥ 15° and valgus angulation in the MA ≥ 10° (based on hip-to-ankle standing radiography) who underwent TKA were divided into four groups. CAS-TKA and conventional TKA outcomes were compared in patients who had preoperative advanced genu varum and advanced genu valgum deformities. The accuracy of component alignment and postoperative limb alignment was determined using radiographic parameters and computed tomography (CT). One hundred and eight patients (144 knees) were included in the analysis. For patients with preoperative advanced genu varum deformity, a significant difference was detected in the sagittal femoral angle (p < 0.001), but no significant improvement of femoral rotational alignment was noted (p = 0.127). In patients with preoperative advanced genu valgum deformity, a significant difference was found in the sagittal femoral angle (p = 0.034). The femoral rotational angle was significantly closer to the proper position in the CAS-TKA group (p < 0.001). When comparing the percentage of knees achieving the proper alignment, there was a decrease in the amount of outlier for the femoral rotational angle for CAS-TKA in advanced genu valgum deformity (p = 0.011). Our data demonstrate that CAS-TKA is beneficial in obtaining proper femoral rotational alignment in patients with advanced genu valgum deformity (preoperative MA ≥ 10° valgus). In patients with advanced genu varum deformity (preoperative MA ≥ 15° varus), CAS-TKA did not improve the femoral rotational alignment.

Highlights

  • Erratum to: Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty

  • Full list of author information is available at the end of the article

  • Research which is freely available for redistribution

Read more

Summary

Introduction

Erratum to: Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty Shih-Jie Lin1, Chien-Ying Lee1, Kuo-Chin Huang1,3, Kuo-Ti Peng1,3, Tsan-Wen Huang1,3*, Mel S. Lee2,3, Robert Wen-Wei Hsu1,3* and Wun-Jer Shen4

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.