Abstract

NMR in BiomedicineVolume 27, Issue 6 p. 738-738 ErratumFree Access Erratum: Orientationally invariant metrics of apparent compartment eccentricity from double pulsed field gradient diffusion experiments This article corrects the following: Orientationally invariant metrics of apparent compartment eccentricity from double pulsed field gradient diffusion experiments Sune Nørhøj Jespersen, Henrik Lundell, Casper Kaae Sønderby, Tim B. Dyrby, Volume 26Issue 12NMR in Biomedicine pages: 1647-1662 First Published online: August 23, 2013 First published: 27 April 2014 https://doi.org/10.1002/nbm.3125Citations: 5AboutSectionsPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinked InRedditWechat This erratum corrects 3 typographical errors in the equations of the appendix of reference 1. In Equation A28, the number multiplying the mean diffusivity should be inverted, and the correct version thus reads: (A28) There is a numerical pre-factor missing in Equation A30, so the correct version is (A30) Finally, in Equation A31, there is an error in the denominator, such that it should have been (A31)where we also substituted TiiTjj = 1. Note also that fractional anisotropy as used here is employing a different normalization (cf. equation A28) than the most widely used. Thus, if FAB denotes the conventionally normalized FA (Equation [15] in 2), we have . When this normalization is employed, FE should be normalized similarly, i.e. multiplied by . These corrections have no influence on the conclusions nor the results (the correct formulas were used in the analysis). References 1 Jespersen SN, Lundell H, Sonderby CK, Dyrby TB. Orientationally invariant metrics of apparent compartment eccentricity from double pulsed field gradient diffusion experiments. NMR Biomed. 2013; 26(12): 1647– 1662. Wiley Online LibraryPubMedWeb of Science®Google Scholar 2 Basser PJ, Pierpaoli C. Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J. Magn. Reson. B 1996; 111(3): 209– 219. CrossrefCASPubMedWeb of Science®Google Scholar Citing Literature Volume27, Issue6June 2014Pages 738-738 ReferencesRelatedInformation

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.