Abstract

Erosion of needle electrodes in the pulsed corona discharge in water with a pulse energy of ∼ 2÷; 3 J was investigated in dependence on the electrode material (platinum, tungsten and stainless-steel) and the solution conductivity (100 and 500 µS/cm). Erosion of electrodes remarkable increased with the higher solution conductivity for all three tested metals. The highest erosion rates were determined for tungsten while platinum was the least eroded material. In addition to the dominant melting effect, release of anode material by the electrolysis significantly contributed to the total erosion of needle electrodes. The highest contribution of electrolysis was determined for stainless-steel electrodes that released up to 40–50% of eroded metal in the form of iron ions. Peculiar protrusions were observed on the surface of eroded tungsten electrodes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.