Abstract
When synthetic materials are used for the construction of pubovaginal slings, urethral erosions may occur. This complication has not been reported with fascial slings. We present a case of a 34-year-old woman who underwent a pubovaginal sling procedure using rectus fascia. After 10 weeks of urinary retention, urethroscopy identified an erosion of the sling at the midurethra. Surgical revision restored normal voiding without recurrent stress incontinence. Although urethral erosions have been reported with synthetic suburethral slings, this case suggests that erosions can also occur with fascial slings. Careful positioning and minimal tension on the sling arms may minimize this risk.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.