Unacceptable levels of surface degradation of metal containment walls and heat exchanger tubing by a combined erosion-corrosion (E-C) mechanism have been experienced in some boilers. The recent use of coatings to protect the heat exchanger tubes of fluidized bed combustor from E-C problems has been suggested by many authors. The laser remelting of the surface coating is suggested as a promising technique to improve its physical properties. Aim of the present investigation is to evaluate the erosion-corrosion (E-C) behaviour of plasma as sprayed and laser remelted Stellite-6 (St-6) coatings on boiler tube steels in the actual coal fired boiler environment. The cyclic experimental studies were performed in the platen superheater zone of a coal fired boiler where the temperature was around 755 °C and the study was carried out upto 10 cycles each of 100 h duration followed by 1 h cooling at ambient temperature. Coated steels were found to possess higher resistance to E-C than the uncoated steels. The highest degradation resistance has been indicated by the T11 steel coated and subsequently laser remelted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.