Abstract

ObjectivesThe aim of this study was to evaluate the pathophysiological features and response to primary percutaneous coronary intervention (PCI) of nonruptured/eroded plaque versus ruptured plaque as a cause of ST-segment elevation myocardial infarction (STEMI). BackgroundAutopsy series identified nonruptured/eroded plaque and ruptured plaque as the principal pathological substrates underlying coronary thrombosis in STEMI. The real incidence of different plaque morphologies, associated biological factors, superimposed thrombus, and their interaction with primary PCI remain largely unknown. MethodsIn a prospective study, 140 patients with STEMI underwent optical coherence tomography of the infarct-related artery (IRA) before PCI, after everolimus-eluting stent implantation and at 9-month follow-up. Histopathology and immunohistochemistry of thrombus aspirates and serum biomarkers were assessed at baseline. ResultsCulprit plaque morphology was adjudicated in 97 patients: 32 plaques (33.0%) with an intact fibrous cap (IFC), 63 (64.9%) plaques with a ruptured fibrous cap (RFC), and 2 (2.1%) spontaneous dissections. Patients with an IFC and RFC had similar clinical characteristics, and serum inflammatory and platelets biomarkers. An IFC presented more frequently with a patent IRA (56.2% vs. 34.9%; p = 0.047), and had fewer lipid areas (lipid-rich areas: 75.0% vs. 100.0%; p < 0.001) and less residual thrombus before stenting (white thrombus: 0.41 mm3 vs. 1.52 mm3; p = 0.001; red thrombus: 0 mm3 vs. 0.29 mm3; p = 0.001) with a lower peak of creatine kinase-myocardial band (66.6 IU/l vs. 149.8 IU/l; p = 0.025). At the 9-month optical coherence tomography, IFC and RFC had similar high rates of stent strut coverage (92.5% vs. 91.2%; p = 0.15) and similar percentage of volume obstruction (12.6% vs. 10.2%; p = 0.27). No significant differences in clinical outcomes were observed up to 2 years. ConclusionsIn the present study, an IFC was observed at the culprit lesion site of one-third of STEMIs. IFC, compared with RFC, was associated with higher rates of patent IRA at first angiography, fewer lipid areas, and residual endoluminal thrombus. However, no difference in vascular response to everolimus-eluting stent was observed. (Optical Coherence Tomography Assessment of Gender Diversity in Primary Angioplasty [OCTAVIA]; NCT01377207)

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call