Abstract

Ergonomic evaluation of thermal comfort is critical for heat stress alleviation systems in the pilot protective helmet, which is few investigated by existing approaches. In this study, CFD simulation under three ventilation pressure differences (60, 160, 260 Pa) and 4 outlet distribution patterns (ODP) was performed. Participants (n = 10) wearing the pilot protective helmet with a ventilation system were exposed to a constant thermal environment, while head skin temperature, subjective thermal sensation and comfort scales and relative humidity were measured. In simulation, head skin temperature changed oppositely to ventilation air pressure differences and increased due to the electronic module. Mean and maximum head skin temperatures were lower under ODP B and D. In experiments, head skin temperature was significantly lower after ventilation of 4 ODPs, while ODP B served optimal cooling effect. This study adds to the existing literature on head thermal comfort evaluation by extending the testing parameters and improving the testing accuracy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call