Abstract
Erbium:yttrium-aluminum-garnet (Er:YAG) laser ablation can effectively resect water-bearing tissues. Application of Er:YAG resection in neurosurgery is complicated by unpredictable bleeding in surgical field. Recently, an integrated theranostic system combining a dual-wavelength laser surgery system using a thulium (Tm) fiber-laser for coagulation and Er:YAG for resection, combined with optical coherence tomography (OCT) guidance was demonstrated for the in vivo resection of tumor tissue. However, lateral thermal spread in the range of 100s of micrometers is common due to lack of vascular specificity using a Tm fiber-laser for coagulation. In this study, a vascular specific ytterbium (Yb) fiber-laser is utilized for enhanced photocoagulation during in vivo neurosurgery improving the precision of Er:YAG tissue resection with minimal lateral thermal spread. Mice underwent stereotactic laser surgery with the proposed Yb/Er:YAG dual wavelength vascular specific neurosurgery in vivo. AnOCTsystem (wavelength range 1310 ± 70 nm) and OCT derived angiography images were used to record cortical images to confirm the coagulation of blood vessels and guide subsequent Er:YAG resection steps. After the laser surgery, mice were killed, and histological analysis was carried out using hematoxylin and eosin staining and Nissl staining to compare the lateral thermal spread with our previously reported Tm/Er:YAG neurosurgery where a continuous wave Tm fiber-laser was used for coagulation. Coagulation scheme using a Yb fiber-laser allowed stoppage of blood flow in disparately sized blood vessels encountered in the mice brain. Histological analysis of murine brain slices post Yb/Er:YAG laser surgery yielded lower thermal spread compared withTm/Er:YAG laser surgery, maximizing the efficiency in both hemostasis (blood flow stoppage) and maximizing tissue ablation efficiency with minimal residual thermal damage zone. In this study, a vascular specific coagulation scheme with Yb/Er:YAG dual-wavelength surgery is presented for neurosurgery. Additionally, Yb/Er:YAG study results are compared with that of a tissue coagulation approach in Tm/Er:YAG surgery previously reported to highlight improved coagulation, reduced nonspecific thermal damage and limited lateral thermal spread. Experimental results suggest that the developed dual-wavelength laser system can effectively resect neural tissues with high localization, minimal lateral thermal spread at the micrometer level while maintaining a bloodless surgical field.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.