Abstract

Objective. The aim of this study was to assess the ability of Er:YAG laser to remove by excision torus mandibularis and to smooth torus palatinus exostosis. Materials and Methods. Torus mandibularis (TM) and torus palatinus (TP) were surgically eliminated via the Er:YAG laser using the following parameters: TM: output power ranging from 500 to 1000 mJ, frequency from 20 to 30 Hz, sapphire tips (diameter 0.8 mm), air-water spray (ratio 5/5), pulse duration 150 μsec, fluence ranging from 99592 J/cm2 to 199044,586 J/cm2. TP: a peeling technique was used to eliminate TP, as excision by slicing being impossible here. Results. TM: excision was obtained after 12730 pulses. TP: smoothing technique took more time compared with excision. Once peeling was considered to be accomplished, the use of a surgical rasp was necessary to eliminate bone spicules that could delay the wound to heal in good conditions. Conclusion. Er:YAG excision (TM) or Er:YAG peeling (TP) are safe clinical techniques easy to practice even if the time required for excision or surface smoothing is more than the time required with bony burs and high speed instruments.

Highlights

  • Tori may be considered as specific exostosis, formed by a highly dense and strictly limited amount of bone marrow, covered with a thin mucosa, easy to flap and poorly vascularised.Their growth is very slow and do not produce any symptoms except in edentulous patients where constructing and wearing partial dentures seems hazardous to impossible.The aetiology of tori is not clear at all [1] even if genetics is supposed to be the most widely accepted factor [2, 3]

  • The aim of this study was to assess the ability of Er:YAG laser to remove by excision torus mandibularis and to smooth torus palatinus exostosis

  • Torus mandibularis (TM) and torus palatinus (TP) were surgically eliminated via the Er:YAG laser using the following parameters: TM: output power ranging from 500 to 1000 mJ, frequency from 20 to 30 Hz, sapphire tips, air-water spray, pulse duration 150 μsec, fluence ranging from 99592 J/cm2 to 199044,586 J/cm2

Read more

Summary

Objective

The aim of this study was to assess the ability of Er:YAG laser to remove by excision torus mandibularis and to smooth torus palatinus exostosis. Torus mandibularis (TM) and torus palatinus (TP) were surgically eliminated via the Er:YAG laser using the following parameters: TM: output power ranging from 500 to 1000 mJ, frequency from 20 to 30 Hz, sapphire tips (diameter 0.8 mm), air-water spray (ratio 5/5), pulse duration 150 μsec, fluence ranging from 99592 J/cm to 199044,586 J/cm. TP: a peeling technique was used to eliminate TP, as excision by slicing being impossible here. Er:YAG excision (TM) or Er:YAG peeling (TP) are safe clinical techniques easy to practice even if the time required for excision or surface smoothing is more than the time required with bony burs and high speed instruments

Introduction
Cases Presentation
Discussion
Conclusion
Full Text