The laser-driven equation-of-state (EOS) experiments for polyimide are presented. The experiments were performed with emission measurements from the rear sides of shocked targets at up to a laser intensity of 10(14) W/cm(2) or higher with 351 nm wavelength and 2.5 ns duration. Polyimide Hugoniot data were obtained up to 0.6 TPa with good accuracy. Applying low-density foam ablator to the EOS unknown material, we also obtained the data at a highest pressure of 5.8 TPa in the nonmetal materials. Those data were in agreement with the theoretical curves.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.