Abstract

A caudal epidural catheter was inserted in 20 premature, high risk infants for abdominal or thoracic surgery under combined caudal epidural and general anaesthesia. Epidurography was used to confirm the position of the catheter which was found to be misplaced in three patients. The catheter penetrated the dura in one case, in another the tip was located in an epidural vessel and in the third the catheter was seen to be curled up within the epidural space. It was concluded that epidurographic control is essential with this method of anaesthesia in very small infants, in whom it was found to provide considerable advantages despite serious risks.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.