Abstract

Study Objective: To test the hypothesis that slow administration of local anesthetic into the epidural space by gravity flow reduces the incidence of signs and symptoms of unintended injection. Design: Prospective, randomized study. Setting: Teaching hospital. Patients: 600 ASA physical status I and II parturients scheduled for labor and delivery or elective cesarean section. Interventions: After identification of the epidural space with pulsations of an air-fluid column, parturients for vaginal delivery (n = 380) were randomized to receive a test dose of 3 ml 3% 2-chloroprocaine with epinephrine 20 μg, two doses of 7 ml bupivacaine 0.03 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow (Group 1) given over 30 seconds or by bolus injection (Group 2) given over 5 seconds through the epidural needle; parturients for Cesarean delivery (n = 220) were randomized to receive a test dose and two doses of 6 ml lidocaine 2 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow or by bolus injection through the epidural needle. Changes in maternal heart rate (HR) and blood pressure, signs of intravascular injection, and adverse effects of epidural bupivacaine-sufentanil were recorded after each dose. Measurements and Main Results: Gravity flow administration (Group 1) was associated with a smaller increase in mean maternal HR ( p < 0.001), less hypotension ( p < 0.01), sedation ( p < 0.01), nausea ( p = 0.01), and segmental spread ( p < 0.0001) than were corresponding doses given by traditional bolus injection (Group 1) for vaginal or Cesarean deliveries. The incidence of systemic toxicity was zero of 300 (0%) with gravity flow and 4 of 300 (1.3%) by bolus injection, p = 0.12, Fisher's exact test. No patient in either group had an accidental intrathecal injection. Conclusion: Gravity flow administration of local anesthetic-opioid solution during epidural block for obstetrics was associated with fewer signs of systemic drug absorption and cardiovascular perturbations than was the traditional bolus injection. This study supports the current opinion that slow administration of local anesthetic during epidural black contributes to fewer adverse events.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.