Abstract
Infections cause significant morbidity and mortality for children receiving maintenance hemodialysis (HD). The Standardizing Care to Improve Outcomes inPediatric End-Stage Kidney Disease (SCOPE) Collaborative is a quality-improvement initiativeaimed at reducing dialysis-associated infections by implementing standardized care practices. This study describes patient-level risk factors for catheter-associated bloodstream infections (CA-BSIs) and examines the association between dialysis center-level compliance with standardized practices and risk of CA-BSI. Prospective cohort study. Children enrolled in SCOPE between June 2013 and July2019. Data were collected on patient characteristics and center-level compliance with HD catheter care practices across the study period. Centers were categorized as consistent, dynamic (improved compliance over the study period), or inconsistent performers based on frequency of compliance audit submission and changes in compliance with HD care practices over time. CA-BSIs. Generalized linear mixed models were used to evaluate (1) patient-level risk factors for CA-BSI and (2) associations between change in center-level compliance and CA-BSIs. The cohort included 1,277 children from 35 pediatric dialysis centers; 1,018 (79.7%) had a catheter and 259 (20.3%) had an arteriovenous fistula or graft. Among children with a catheter, mupirocin use at the catheter exit site was associated with an increased rate of CA-BSIs (rate ratio [RR], 4.45; P= 0.004); the use of no antibiotic agent at the catheter exit site was a risk factor of borderline statistical significance (RR, 1.79; P= 0.05). Overall median compliance with HD catheter care practices was 87.5% (IQR, 77.3%-94.0%). Dynamic performing centers showed a significant decrease in CA-BSI rates over time (from 2.71 to 0.71 per 100 patient-months; RR, 0.98; P< 0.001), whereas no significant change in CA-BSI rates was detected among consistent or inconsistent performers. Lack of data on adherence to HD care practices on the individual patient level. Improvement in compliance with standardized HD care practices over time may lead to a reduction in dialysis-associated infections.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.