Abstract

We describe a double-antibody enzyme immunoassay for determination of free thyroxin (FT4) in dried blood samples on filter paper, with use of a T4-beta-D-galactosidase complex. The measurable range of FT4 concentration in two 3-mm blood discs, each of which contained about 2.7 microL of blood, was 1.9 to 93 ng/L, as determined by comparison with concentrations of FT4 in known serum standards. FT4 in blood samples dried on filter paper was stable for at least four weeks when kept dry at -20 degrees C, room temperature, or 37 degrees C. The mean coefficients of variation were 7.6% (within assay) and 6.4% (between assays). Results for FT4 by this method correlated well with those for serum determined by radioimmunoassay (r = 0.98). The proposed method can be used to differentiate persons with hyper- and hypothyroidism from normal subjects and those with abnormal concentrations of thyroxin-binding globulin. The procedure seems suited for screening studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.